SIOL-M12B-16SAPSIOL-M12B-16SAP M12 IO-Link hub, 16 self-configuring PNP digital I/O channels
SIOL-M12B-16SAP is a self-configuring M12 IO-Link hub with 16 PNP digital I/O channels rated 0.2 A per output. It has one M12 A-coded Class B IO-Link V1.1 interface, a shared power supply for the module and load, electronics potted in resin and IP67 protection.
IO-LinkM12 hubsIP67M12PNP







Features
IO-Link remote self-configuring I/O device
16-channel digital input, M12 5-pin sockets
16-channel digital output, 0.2 A per channel
IO-Link V1.1
M12 A-coded, IO-Link standard Class B interface
Shared power supply for module and load
Shock and vibration resistant
Electronics potted in resin
IP67 protection
Specifications
- Supply voltage
- 24VDC ± 10%
- Operating current
- < 100mA
- Working and load power supply
- ≤4A (Ul Ub) Note: IO-Link Master provides power, Master parameters must be considered
Input
- Number of channels
- 16(C0-C7)
- Connectivity type
- M12, 5-pin
- Input type
- PNP
- Input impedance
- 3K
- Input rated current
- 7mA
- Input delay
- 3ms
- Switch threshold
- 2mA/4mA 7V/11V
- Electrical isolation mode
- Optocoupler isolation
- Sensor power supply
- Maximum 150mA C0...C3 Total current max 1.2 A C4...C7 Total current max 1.2 A The total C0-C7 current is limited to the maximum current of the Master port
Output
- Number of channels
- 16(C0-C7)
- Output type
- PNP
- Output current
- 0.2A;Max.0.5A;(Total max current<4A)
- Output protection
- Overload protection, overheating protection
- Output protection reaction time
- Approximately 20ms
- Switching frequency
- 100HZ
- Output voltage drop
- 0.6V
- Electrical Isolation mode
- Optocoupler isolation
IO-Link
- Process data
- 2 bytes input,2 bytes output
- Vendor ID
- 1317 (0x0525)
- Device ID
- 66128 (0x010250)
- Number of ports
- 1
- IO-Link specification
- V1.1
- IO-Link port type
- Class B
- Frame type
- TYPE_2_V
- Transmission rate
- COM2 38.4 kbit/s
- Minimum cycle time
- 4000us
- ISDU
- Supported
- Block parameter operation
- Not support
- Data storage (DS)
- Supported
- Data storage lock
- Supported Note: This function is supported for compatibility, but the device will not perform this operation.
- Operating temperature
- -20-55℃
Documents
Configuration fileVersion IODD 1.1 / 2024-11-11
SIOL-M12B-16SAP IODD file
For models: SIOL-M12B-16SAPOrder codes: 78320044Updated: 2026-08-20Size: 40.9 KB
CAD drawing (DWG)
SIOL-M12B-16SAP CAD drawing (DWG)
For models: SIOL-M12B-16SAPOrder codes: 78320044Updated: 2026-08-20Size: 154.6 KB
3D model (STP)
SIOL-M12B-16SAP 3D model (STP)
For models: SIOL-M12B-16SAPOrder codes: 78320044Updated: 2026-08-20Size: 536.2 KB
EPLAN
SIOL-M12B-16SAP EPLAN
For models: SIOL-M12B-16SAPOrder codes: 78320044Updated: 2026-08-20Size: 8.1 MB
Datasheet
SIOL-M12B-16SAN / SIOL-M12B-16SAP datasheet
For models: SIOL-M12B-16SAN / SIOL-M12B-16SAPOrder codes: 78320045 / 78320044Updated: 2026-10-13Size: 0.90 MiB
Accessories
Accessories and connectivity
Published accessory products; open any of them for full details.
Compare models in this series
All M12 hubs (37)| Model | Operating voltage | Current consumption | Supply current | Input channels | View details | |
|---|---|---|---|---|---|---|
![]() | SIOL-M12B-16SAPThis model | 24VDC ± 10% | < 100mA | ≤4A (Ul Ub) Note: IO-Link Master provides power, Master parameters must be considered | 16(C0-C7) | |
![]() | SIOL-M12B-16SANSame specifications | 24VDC ± 10% | < 100mA | ≤4A (Ul Ub) Note: IO-Link Master provides power, Master parameters must be considered | 16(C0-C7) | → |
![]() | SIOL-M12B-16SAN/EXSame specifications | 24VDC ± 10% | < 100mA | ≤4A (Ul Ub) Note: IO-Link Master provides power, Master parameters must be considered | 16(C0-C7) | → |
![]() | SIOL-M12B-16SAP/EXSame specifications | 24VDC ± 10% | < 100mA | ≤4A (Ul Ub) Note: IO-Link Master provides power, Master parameters must be considered | 16(C0-C7) | → |